With default config on smdk5250 latest tree throws below message:
[ 2.226049] thermal thermal_zone0: critical temperature reached(224 C),shutting down
[ 2.227840] reboot: Failed to start orderly shutdown: forcing the issue
and hangs randomly because it reads wrong temperature value.
I can't figure out any direct relation between LDO10 and TMU from board
schematics which I have. So making LDO10 always-on to fix issue for now.
Signed-off-by: Yadwinder Singh Brar <[email protected]>
[pankaj.dubey: resubmitted after rebasing to latest kgene tree]
Signed-off-by: Pankaj Dubey <[email protected]>
Tested-by: Pankaj Dubey <[email protected]>
Signed-off-by: Krzysztof Kozlowski <[email protected]>
regulator-name = "P1.8V_LDO_OUT10";
regulator-min-microvolt = <1800000>;
regulator-max-microvolt = <1800000>;
+ regulator-always-on;
};
ldo11_reg: LDO11 {