In a refactor, the watermark clock inputs to
powerplay from DC were changed from units of 10kHz to
kHz clocks.
One division by 100 was not converted into a division
by 1000.
Signed-off-by: David Francis <[email protected]>
Reviewed-by: Harry Wentland <[email protected]>
Signed-off-by: Alex Deucher <[email protected]>
table->WatermarkRow[1][i].MaxClock =
cpu_to_le16((uint16_t)
(wm_with_clock_ranges->wm_dmif_clocks_ranges[i].wm_max_dcfclk_clk_in_khz) /
- 100);
+ 1000);
table->WatermarkRow[1][i].MinUclk =
cpu_to_le16((uint16_t)
(wm_with_clock_ranges->wm_dmif_clocks_ranges[i].wm_min_mem_clk_in_khz) /