ARM: dts: Fix wrong compatible string for Exynos3250 ADC
authorChanwoo Choi <[email protected]>
Tue, 22 Jul 2014 02:04:00 +0000 (03:04 +0100)
committerJonathan Cameron <[email protected]>
Wed, 23 Jul 2014 20:59:03 +0000 (21:59 +0100)
This patchset fix wrong compatible string for Exynos3250 ADC. Exynos3250 SoC
need to control only special clock for ADC. Exynos SoC except for Exynos3250
has not included special clock for ADC. The exynos ADC driver can control
special clock if compatible string is 'exynos3250-adc-v2'.

Signed-off-by: Chanwoo Choi <[email protected]>
Acked-by: Kyungmin Park <[email protected]>
Reviewed-by: Tomasz Figa <[email protected]>
Acked-by: Kukjin Kim <[email protected]>
Acked-by: Arnd Bergmann <[email protected]>
Signed-off-by: Jonathan Cameron <[email protected]>
arch/arm/boot/dts/exynos3250.dtsi

index 3e678fa335bf7dc2981bb3a7c7a19f6871f68617..aaaac798120012d66abdfaa83c010ac36b8123e5 100644 (file)
                };
 
                adc: adc@126C0000 {
-                       compatible = "samsung,exynos-adc-v3";
+                       compatible = "samsung,exynos3250-adc",
+                                    "samsung,exynos-adc-v2";
                        reg = <0x126C0000 0x100>, <0x10020718 0x4>;
                        interrupts = <0 137 0>;
-                       clock-names = "adc", "sclk_tsadc";
+                       clock-names = "adc", "sclk";
                        clocks = <&cmu CLK_TSADC>, <&cmu CLK_SCLK_TSADC>;
                        #io-channel-cells = <1>;
                        io-channel-ranges;