Reboot or shutdown during delayed works could corrupt communication with
EC and certain I2C controller may not be able to recover from the error
state.
This patch registers a shutdown callback used to cancel the debugfs log
worker thread.
Signed-off-by: Daniel Hung-yu Wu <[email protected]>
Signed-off-by: Enric Balletbo i Serra <[email protected]>
Reviewed-by: Andy Shevchenko <[email protected]>
Signed-off-by: Lee Jones <[email protected]>
return 0;
}
+static void ec_device_shutdown(struct platform_device *pdev)
+{
+ struct cros_ec_dev *ec = dev_get_drvdata(&pdev->dev);
+
+ /* Be sure to clear up debugfs delayed works */
+ cros_ec_debugfs_remove(ec);
+}
+
static const struct platform_device_id cros_ec_id[] = {
{ DRV_NAME, 0 },
{ /* sentinel */ },
},
.probe = ec_device_probe,
.remove = ec_device_remove,
+ .shutdown = ec_device_shutdown,
};
static int __init cros_ec_dev_init(void)