ar71xx: add support for TP-Link Archer C60 v2
authorHenryk Heisig <[email protected]>
Mon, 15 Jan 2018 05:44:14 +0000 (06:44 +0100)
committerPiotr Dymacz <[email protected]>
Fri, 6 Apr 2018 22:09:05 +0000 (00:09 +0200)
TP-Link Archer C60 v2 is a dual-band AC1350 router, based on
Qualcomm/Atheros QCA9561 + QCA9886.

Specification:

- 775/650/258 MHz (CPU/DDR/AHB)
- 64 MB of RAM (DDR2)
- 8 MB of FLASH (SPI NOR)
- 3T3R 2.4 GHz
- 2T2R 5 GHz
- 5x 10/100 Mbps Ethernet
- 7x LED, 2x button
- UART header on PCB

Flash instruction (web):

Download lede-ar71xx-generic-archer-c60-v2-squashfs-factory.bin and use
OEM System Tools - Firmware Upgrade site.

Flash instruction (recovery):

1. Set PC to fixed IP address 192.168.0.66
2. Download lede-ar71xx-generic-archer-c60-v2-squashfs-factory.bin and
   rename it to tp_recovery.bin
3. Start a tftp server with the file tp_recovery.bin in its root
   directory
4. Turn off the router
5. Press and hold reset button
6. Turn on router with the reset button pressed and wait ~15 seconds
7. Release the reset button and after a short time the firmware should
   be transferred from the tftp server
8. Wait ~30 second to complete recovery

Flash instruction (under U-Boot, using UART):

tftp 0x81000000 lede-ar71xx-...-sysupgrade.bin
erase 0x9f030000 +$filesize
cp.b $fileaddr 0x9f030000 $filesize
reset

Signed-off-by: Henryk Heisig <[email protected]>
src/tplink-safeloader.c

index eb99241136b2f1c82d0e8ae43f7f66f768c18098..2e83b71c44e67fbcf184ca78129cbedfe92923d8 100644 (file)
@@ -451,6 +451,43 @@ static struct device_info boards[] = {
                .last_sysupgrade_partition = "file-system",
        },
 
+       /** Firmware layout for the C60v2 */
+       {
+               .id     = "ARCHER-C60-V2",
+               .vendor = "",
+               .support_list =
+                       "SupportList:\r\n"
+                       "{product_name:Archer C60,product_ver:2.0.0,special_id:42520000}\r\n"
+                       "{product_name:Archer C60,product_ver:2.0.0,special_id:45550000}\r\n"
+                       "{product_name:Archer C60,product_ver:2.0.0,special_id:55530000}\r\n",
+               .support_trail = '\x00',
+               .soft_ver = "soft_ver:2.0.0\n",
+
+               .partitions = {
+                       {"factory-boot", 0x00000, 0x1fb00},
+                       {"default-mac", 0x1fb00, 0x00200},
+                       {"pin", 0x1fd00, 0x00100},
+                       {"product-info", 0x1fe00, 0x00100},
+                       {"device-id", 0x1ff00, 0x00100},
+                       {"fs-uboot", 0x20000, 0x10000},
+                       {"os-image", 0x30000, 0x180000},
+                       {"file-system", 0x1b0000, 0x620000},
+                       {"soft-version", 0x7d9500, 0x00100},
+                       {"support-list", 0x7d9600, 0x00100},
+                       {"extra-para", 0x7d9700, 0x00100},
+                       {"profile", 0x7d9800, 0x03000},
+                       {"default-config", 0x7dc800, 0x03000},
+                       {"partition-table", 0x7df800, 0x00800},
+                       {"user-config", 0x7e0000, 0x0c000},
+                       {"certificate", 0x7ec000, 0x04000},
+                       {"radio", 0x7f0000, 0x10000},
+                       {NULL, 0, 0}
+               },
+
+               .first_sysupgrade_partition = "os-image",
+               .last_sysupgrade_partition = "file-system",
+       },
+
        /** Firmware layout for the C5 */
        {
                .id = "ARCHER-C5-V2",
@@ -1343,6 +1380,7 @@ static void build_image(const char *output,
 
        /* Some devices need the extra-para partition to accept the firmware */
        if (strcasecmp(info->id, "ARCHER-C25-V1") == 0 ||
+           strcasecmp(info->id, "ARCHER-C60-V2") == 0 ||
            strcasecmp(info->id, "TLWR1043NV5") == 0) {
                const char mdat[11] = {0x00, 0x00, 0x00, 0x02, 0x00, 0x00, 0x00, 0x00, 0x01, 0x00, 0x00};
                parts[5] = put_data("extra-para", mdat, 11);