When configuring FPS during probe, assuming a DT node is present for
FPS, the code can run into a problem with the switch statements in
max77620_config_fps() and max77620_get_fps_period_reg_value(). Namely,
in the case of chip->chip_id == MAX77620, it will set
fps_[mix|max]_period but then fall through to the default switch case
and return -EINVAL. Returning this from max77620_config_fps() will
cause probe to fail.
Signed-off-by: Rhyland Klein <[email protected]>
Reviewed-by: Laxman Dewangan <[email protected]>
Reviewed-by: Thierry Reding <[email protected]>
Tested-by: Thierry Reding <[email protected]>
Tested-by: Alexandre Courbot <[email protected]>
Signed-off-by: Lee Jones <[email protected]>
break;
case MAX77620:
fps_min_period = MAX77620_FPS_PERIOD_MIN_US;
+ break;
default:
return -EINVAL;
}
break;
case MAX77620:
fps_max_period = MAX77620_FPS_PERIOD_MAX_US;
+ break;
default:
return -EINVAL;
}