davinci: am18x/da850/omap-l138: use 'NOM' voltage defined in datasheet as min voltage
authorSekhar Nori <[email protected]>
Wed, 7 Jul 2010 08:32:49 +0000 (14:02 +0530)
committerKevin Hilman <[email protected]>
Fri, 24 Sep 2010 14:40:24 +0000 (07:40 -0700)
For each DA850 OPP, the normal ('NOM') voltage defined in the tecnical
reference manual (TRM) is actually the minimum voltage the frequency
is supported at.

The minimum ('MIN') voltage defined in TRM is meant to take care of
voltage fluctuations and the device should not be run at this voltage
for extended periods of time.

Fix the OPP definitions to define the cvdd_min as the normal voltage
defined in the datasheet.

Signed-off-by: Sekhar Nori <[email protected]>
Signed-off-by: Kevin Hilman <[email protected]>
arch/arm/mach-davinci/da850.c

index 868227e66cea078141e199e6c08a02be10c07517..6932d804556bb7d8616987f7d3dea8aa13b9b9f9 100644 (file)
@@ -851,7 +851,7 @@ static const struct da850_opp da850_opp_300 = {
        .prediv         = 1,
        .mult           = 25,
        .postdiv        = 2,
-       .cvdd_min       = 1140000,
+       .cvdd_min       = 1200000,
        .cvdd_max       = 1320000,
 };
 
@@ -860,7 +860,7 @@ static const struct da850_opp da850_opp_200 = {
        .prediv         = 1,
        .mult           = 25,
        .postdiv        = 3,
-       .cvdd_min       = 1050000,
+       .cvdd_min       = 1100000,
        .cvdd_max       = 1160000,
 };
 
@@ -869,7 +869,7 @@ static const struct da850_opp da850_opp_96 = {
        .prediv         = 1,
        .mult           = 20,
        .postdiv        = 5,
-       .cvdd_min       = 950000,
+       .cvdd_min       = 1000000,
        .cvdd_max       = 1050000,
 };