When fixing things to avoid ambiguous cases I had a thinko
and included SIGPOLL/SIGIO in with all of the other signals
that have signal specific si_codes. Which is completely wrong.
Fix that.
Reported-by: Vince Weaver <[email protected]>
Signed-off-by: "Eric W. Biederman" <[email protected]>
* specific si_codes. In that case use SI_SIGIO instead
* to remove the ambiguity.
*/
- if (sig_specific_sicodes(signum))
+ if ((signum != SIGPOLL) && sig_specific_sicodes(signum))
si.si_code = SI_SIGIO;
/* Make sure we are called with one of the POLL_*