Read access to the SPI flash are broken on da850-evm, i.e. the data
read is not what is actually programmed on the flash.
According to the datasheet for the M25P64 part present on the da850-evm,
if the SPI frequency is higher than 20MHz then the READ command is not
usable anymore and only the FAST_READ command can be used to read data.
This commit specifies in the DTS that we should use FAST_READ command
instead of the READ command.
Cc: [email protected]
Tested-by: Kevin Hilman <[email protected]>
Signed-off-by: Fabien Parent <[email protected]>
[
[email protected]: subject line adjustment]
Signed-off-by: Sekhar Nori <[email protected]>
Signed-off-by: Olof Johansson <[email protected]>
#size-cells = <1>;
compatible = "m25p64";
spi-max-frequency = <30000000>;
+ m25p,fast-read;
reg = <0>;
partition@0 {
label = "U-Boot-SPL";