The current 10ms timeout is too short for some normal USBTMC device
operation, increase it to a value which was tested with previously
affected Tektronix oscilloscopes.
Signed-off-by: Gergely Imreh <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
#define USBTMC_SIZE_IOBUFFER 2048
/* Default USB timeout (in milliseconds) */
-#define USBTMC_TIMEOUT 10
+#define USBTMC_TIMEOUT 5000
/*
* Maximum number of read cycles to empty bulk in endpoint during CLEAR and