In order to enable temperature mode aka automatic mode for the F75373 and
F75375 chips, the two FANx_MODE bits in the fan configuration register
need be set to 01, not 10.
Signed-off-by: Nikolaus Schulz <[email protected]>
Cc: [email protected] # 2.6.32+
Signed-off-by: Guenter Roeck <[email protected]>
fanmode |= (3 << FAN_CTRL_MODE(nr));
break;
case 2: /* AUTOMATIC*/
- fanmode |= (2 << FAN_CTRL_MODE(nr));
+ fanmode |= (1 << FAN_CTRL_MODE(nr));
break;
case 3: /* fan speed */
break;